Steam Traps must have sufficient discharge capacity of air and water during warm up and radiation losses, but must prevent leakage of high pressure steam which is very costly and can also damage downstream equipment Very few trap designs are available for handling condensate at high pressure STEAM TRAPPING IN POWER PLANTS

Yarway Steam Traps The Industrial Steam Trapping Handbook The leading name in steam traps 2 it is happening If each failed trap had high visibility, it would be a different story but with traps discharging into a closed return system the same telltale plumes of vapor, that quickly

A main drip trap should be used every 100 150 feet of straight piping run Traps should be used at each change of piping elevation and at risers as well as in front of expansion loops The condensate load in a typical main drip application is small It is unusual for main drip steam traps

A main drip trap should be used every 100 150 feet of straight piping run Traps should be used at each change of piping elevation and at risers as well as in front of expansion loops The condensate load in a typical main drip application is small It is unusual for main drip steam traps

Start studying High Pressure Steam Traps 305 j Learn vocabulary, terms, and more with flashcards, games, and other study tools

A steam trap is a self contained valve which automatically drains the condensate from a steam containing enclosure while remaining tight to live steam, or if necessary, allowing steam to flow at a controlled or adjusted rate Most steam traps pass non condensable gases like air while remaining tight to live steam

Jun 06, 2016 Surprised? Its true If the load is the same in both cases, the low pressure steam will move through the pipes much more quickly than the high pressure steam The reason is simple: High pressure steam fits into a smaller space than low pressure steam The pressure squeezes it You wind up with less volume

It's pretty obvious, really An efficient steam trap wastes less energy, which means you burn less fuel and reduce emissions The results are energy savings and a cleaner, healthier environment By helping companies manage energy, Armstrong steam traps are also helping protect the world we all share

A typical example is the draining of condensate from steam traps installed on main utility steam lines As vertical and horizontal distances increase, the system backpressure will also increase The ejector overcomes the pressure drop by feeding pressurized high temperature condensate into the centrifugal pump, making it possible to pump

to Table 45 2 for 15 psig steam With a pressure drop of 1 0 psi per 100 feet, a 5 pipe will give a flow of 6,160 lbs/hr On the basis of pressure drop only, a 5 pipe Traps and High Back Pressure Back pressures excessive by normal standards may occur due to

We manufacture a lot of OEM steam traps for jacketed kettles by Market Forge, Blodgett, Vulcan etc if the trap is one of ours I can probably make some recommendations based on the condensate loads just need to know the model Many of the lower pressure traps just don't cope well with high pressure and have a short lifespan

An extensive range of bimetallic steam traps, for applications ranging from standard steam lines to superheated steam If you wish to learn more about the Velan steam trap line or traps in general, please visit

Back PressureSteam Trap Capacity A high percentage of steam trap applications will have back pressures above atmospheric at the discharge side of the steam trap caused by the condensate return system The back pressure may be unintentional or deliberately produced by the design or the operation of the condensate return system

A steam trap is a device used to discharge condensates and non condensable gases with a negligible consumption or loss of live steam Most steam traps are nothing more than automatic valves They open, close or modulate automatically The three important functions of steam traps are:

Steam traps and steam trapping How steam traps work and why steam traps are necessary All is explained in this block, along with the different types, where they are used, and how they are selected Air venting theory and applications are touched upon, along with steam trap maintenance

Jun 23, 2014 Why you can't use high pressure steam boilers on low pressure steam systems Why you can't use high pressure steam boilers on low pressure steam systems The contractor had changed some of the steam traps from high pressure to low pressure by replacing the seats What he hadn't counted on, though, was that some of the traps discharged to

Find High Pressure Steam Traps related suppliers, manufacturers, products and specifications on GlobalSpec a trusted source of High Pressure Steam Traps information

Jun 29, 2019 Steam traps in high pressure steam drip service shall preferably be inverted bucket style mechanical traps Steam traps provided for steam turbine inlet drip service shall be a thermodynamic piston type trap A commonly accepted practice is to use float thermostatic FT steam traps for low pressure steam systems up to 30 PSIG, and

The valve stays shut until the steam pressure above the disc drops, allowing the valve to open and the discharge cycle to repeat The Cameron DOUGLAS ITALIA Model DA is an example of this type of trap, which can be used in steam mains and steam tracing applications Applications Steam traps can be used anywhere there is a steam system and a

Condensate is drained from the steam process through a steam trap The steam trap discharges to a vented condensate receiver system When con densate is drained from the process at a given pressure 150 psi and passes through a steam trap to a lower pressure 0 psi @ 212°F, then a percentage of the condensate will flash to steam

Start studying High Pressure Steam Traps 305 j Learn vocabulary, terms, and more with flashcards, games, and other study tools

Watson McDaniel has been proudly manufacturing high quality steam and fluid specialty products for the industrial marketplace since 1878 An ISO 9001 Certified and ASME Qualified manufacturing company with products made in USA

saturated steam pressure at the inlet of the steam trap The outlet temperature The sensitivity of most high frequency monitoring equipment allows the testing person to hear not only completely failed Testing steam traps can be very easy if the plant provides the correct equipment,

to Table 45 2 for 15 psig steam With a pressure drop of 1 0 psi per 100 feet, a 5 pipe will give a flow of 6,160 lbs/hr On the basis of pressure drop only, a 5 pipe Traps and High Back Pressure Back pressures excessive by normal standards may occur due to

Spirax Sarco is the world leader in high quality products for the control and efficient use of steam and other industrial fluids Robust and high performance controls to meet pressure, temperature and safety requirements, from simple self acting controls to complex systems Steam Traps Steam trapping solutions that effectively remove

to Table 45 2 for 15 psig steam With a pressure drop of 1 0 psi per 100 feet, a 5 pipe will give a flow of 6,160 lbs/hr On the basis of pressure drop only, a 5 pipe Traps and High Back Pressure Back pressures excessive by normal standards may occur due to

Home Product Solutions Free Float® Steam Traps for High Temperature, High Pressure Use Free Float® Steam Traps for High Temperature, High Pressure Use Get a Quote Printable PDF Overview Used on a Variety of High Temperature, High Pressure Steam using Equipment

One typical steam trap assembly and one strainer blowdown is provided on the strainer blowdown port Steam trap assembly is connected to a vented flash tank, and is not connected to any high pressure condensate main Blowdown piping terminates at a floor drain or other drain so that strainer blowdown operation does not result in water on the floor

With bad Steam Traps blowing steam into Condensate Pipes, the steam will travel the path of least resistance and pressurize the outlets side of the Steam Traps This can often lead to the reduction or elimination of pressure differential across the trap, usually resulting in Steam Equipment malfunction and temperature fluctuations

Spirax Sarco releases the FT62 range of high pressure float and thermostatic steam traps Page Content Spirax Sarco, the leader in products and services for steam system management, announces the release of the FT62 range of ASME 600 float and thermostatic steam traps

Different operating principles for different steam system requirements Bi metallic traps for tracing and high pressure, balanced pressure traps for air venting and small heat exchange plate, ball float traps for high capacity and variable load, thermodynamic traps

An extensive range of bimetallic steam traps, for applications ranging from standard steam lines to superheated steam If you wish to learn more about the Velan steam trap line or traps in general, please visit

Steam Traps Back Pressure and Capacity A back pressure in a condensate systems will reduce steam trap capacity Sponsored Links Steam trap capacities are reduced if there is a back pressure in the condensate system A back pressure can be the result of excessive flash steam generation

the escape of steam As with inverted bucket traps, float and thermostatic traps rely on a fixed force the buoyancy of the float Discharge orifices must be sized by differential pressure Placing a low pressure float and thermostatic trap in high pressure service will result in the trap locking up A contrasting characteristic of both the

Spirax Sarco thermodynamic steam traps are found on high pressure steam applications such as tracer lines and industrial process equipment The single operating component within the thermodynamic steam trap is the disc Thermodynamic traps feature an

Condensate is drained from the steam process through a steam trap The steam trap discharges to a vented condensate receiver system When con densate is drained from the process at a given pressure 150 psi and passes through a steam trap to a lower pressure 0 psi @ 212°F, then a percentage of the condensate will flash to steam

Armstrong bucket steam traps are a robust mechanical steam trap available for pipe sizes from 1/2 to 2 1/2 Bucket steam traps are widely used on both low pressure steam heating systems 15 psi and under as well as higher steam pressures up to 950 psi

Dec 01, 2015 Whenever steam condenses in a process, it creates hot liquid condensate It is the role of steam traps to remove condensate from steam lines and process equipment with a minimum loss of live steam

 
Copyright © 2017 Shandong Xinhai Mining Technology & Equipment Inc